No broken or loose wires visible. Welcome to Pool Spa Outpost! If so, is there power coming into the clock (on the line terminals)? I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Trippers are not installed properly Re-install trippers on dial 2. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. I have a T104. I looked through the visual motor check and the gear still moving fine. Copyright 2022 In The Swim. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Theres really only 3 causes as to why your pump wont turn on/off. You can replace the entire mechanism or the gears. Hi Matthew T104 can only turn one pump on and off. Wired correctly, #10 wire, nothing. by pool co. , so wondered about the cost. "@type": "Organization",
Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts It is a mechanical issue between the trippers and the switch lever. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Are the gears engaged, in the center, behind the dial? Any other thoughts? 3. "caption": "In The Swim Blog"
So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. It is still moving and it will trip off but not on. Below is a breakdown of how to wire different Intermatic timer models. PDF Model: T104 24 Hour Dial Time Switch The on/off pins are tight and pretty new stillany thoughts? I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Also check that the motor number is compatible with your clock model. When I put the new one on, the trippers do not work. it could also be a failing breaker, but that would be a last resort. If you use our referring links, it costs you nothing extra. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Sometimes you will find the timer appears to be working, that is the clock dial is turning and you can see the gears behind the clock turning, but the pump isnt being switched on or off. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. Your incoming power leads should connect to terminals 1 and 3, and the wires that lead to the pump, should be connected to terminals 2 and 4. David, check the wiring, the power in and power out wires may be reversed. Any advice on how to fix. The other gears move very slowly, and appear to not move at all, except for one I believe? Ive seen it happen from lightning strikes, or insect infestation. My timer works good it turns on and off when I set the time. When I turned it back on now the pool clock goes backwards. Hey there! Or one of the wires may have broken, or lost the protective plastic insulation. It stays on until I turn off the circuit breaker. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. We cover T101, T103 and T104 models of mechanical pool timers. Just installed a new timer. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. It should be 110V or 220V AC. DEWENWILS Outdoor Outlet Box. I replaced the pump and still nothing is moving. You can find this in your power board. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. "logo": {
Black goes to _1 I have a sweeper set on auto on the second timer and it is working correctly. OPEN TODAY, 12PM TO 3PM. BUILT BY HAND IN QUEENS, NYC. To set it, you just move the on/off "trippers" where you want them. It could also be loose wires, either on the time clock terminal board, or on the timer motor. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. We may earn a small commission. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Slide it around the pool timer dial to the correct start time and re-tighten it. If its not, then the timer will not turn on/off at the correct times. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. I noticed that the on flipper was a little bit bent so I replaced it with new one. Or might find something else. The clock is powered from the Line 1 terminal correct? Terminal A (farthest to the left side) is not connected to anything. Theres an issue with the wiring between the circuit breaker and the timer. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. Ill do the same. Hi Bev, seems legit to me! Pools are not cheap! Align the bar with the current time and push it back into place. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. It is an ON tripper right? You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. },
If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. Some of the replacement motors make it past quality control with the incorrect gear setup. Make sure the middle time pointer is tight. Hi, Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . That should quiet it down. Look into the visual motor check window, near the top of the timer mechanism. Does the tripper work on other areas of the clock, like near the off tripper? The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. "height": "219",
The mechanism for the off tripper doesn't work at all when manually depressed. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . With this model can I control both of these motors with two different on and off times. First time pool owner, Pool timer and trippers not working properly When you flip the switch does it separate and reconnect the tabs? You can check these easily by removing them and inspecting them for damage. You most likely just need to now set the pins and the clock and your timer will work. Why do we stock so many pool parts? Recently i just notice my T104R timer a bit noisier than usual. For Sale: 2 beds, 2 baths 1152 sq. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. NEW CONSTRUCTION. 220V clocks have 5 terminals, 110V clocks have 3 terminals. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Any ideas? Intermatic Pool Timer Troubleshooting - In The Swim Pool Blog HI Jeff, do you have power outages sometimes? My timer doesnt seem to be working or my pump in either speed. After a power failure the timer clock can start up backwards, mine has done this several times. Not sure if you still answer these but I have a weird one for you. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. I have an intermatic timer thats 2 years young. You need extreme care in this next step. Hi Doug, Check the wiring. Should I go ahead and spray it anyway? Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Second thing to check is the dial bent or warped, in that area where the on tripper is? Amazon.com: pool timer trippers You will want to make sure the manual switch under the timer wheel is pushed to the on position. However, intermittently after the ON tripper switches pump on the pump will stop. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. Does the motor gradually start running slowly? Once you have confirmed that you timer is working you will need to adjust the timer pins to reflect the time you want your filter system to turn on and off. "wordCount": "1259",
Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. Did you try to flip the switch of the timeclock? Does this give you a better idea of the problem? If you are not sure if your timer is working or not you will first need to know if its even operational. Hi Sandra, does the on/off tab switch crisply, or softly? Now ever sense I did that last week my timer wont shut off or turn on my pool pump. Is this broken? I bought a new timer and replace the T104 timer clock. The timer quit after a nearby lightning strike. Video of the Day Trippers i have an oval pool that is closed for the winter but there ha been a problem. These clocks determine when your pool pump turns on, and how long it runs. I am using the breaker to turn on and off the pool pump. May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Is it toast ? "keywords": "",
Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Garden Guides | How to Troubleshoot a Swimming Pool Timer This product is certified by Amazon to work with Alexa. "@type": "Person",
Not two OFF trippers? "name": "In The Swim",
Or may be bent and not come together. Wont power on pump but can hear timer clicking away. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. It started lagging again a week or so ago. (usually not). Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Replaced complete new timer assuming 5 years perfect service probably wore it out. Date Listed: 18/02/2023; . Still no luck. Replace the gears if this is an issue. Found the answer. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well.
Joanna Gaines Focaccia Bread, Government Grants For Cemetery Restoration, Tom Pendergast Family Tree, How To Become An Ophthalmologist In Nigeria, Articles P